TEYU industrial chiller CW-5000 can provide perfect cooling for up to 120W CO2 DC laser tubes. This small water chiller has a small footprint, saving a lot of space for CO2 laser engraving and cutting machine users. The temperature control accuracy of the CW-5000 chiller is ±0.3°C with a cooling capacity of up to 750W. Mini laser chiller CW-5000 is capable of providing superior active cooling. 

Industrial chiller CW-5000 has multiple choices of water pumps and optional 220V or 110V powers. Designed with intelligent temperature control function, this portable water chiller unit can keep your CO2 laser tube at a water temperature you preset, automatically adjusting the temperature for you to avoid the occurrence of condensate water.

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    Industrial Water Chiller CW-5000 for CO2 Glass Laser Tube

    Model: CW-5000

    Machine Size: 58X29X47cm (L X W X H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    ModelCW-5000TGTYCW-5000DGTYCW-5000TITYCW-5000DITY
    VoltageAC 1P 220-240VAC 1P 110VAC 1P 220-240VAC 1P 110V
    Frequency50/60Hz60Hz50/60Hz60Hz
    Current0.4~2.8A0.4~5.2A0.4~3.7A0.4-6.3A

    Max. power consumption

    0.4/0.46kW0.47kW0.48/0.5kW0.53kW


    Compressor power

    0.31/0.37kW0.36kW0.31/0.38kW0.36kW
    0.41/0.49HP0.48HP0.41/0.51HP0.48HP



    Nominal cooling capacity

    2559Btu/h
    0.75kW
    644Kcal/h
    Pump power0.03kW0.09kW

    Max. pump pressure

    1bar2.5bar

    Max. pump flow

    10L/min15L/min
    RefrigerantR-134a
    Precision±0.3℃
    ReducerCapillary
    Tank capacity6L
    Inlet and outletOD 10mm Barbed connector10mm Fast connector
    N.W.18Kg19Kg
    G.W.20Kg23Kg
    Dimension58X29X47cm (L X W X H)
    Package dimension65X36X51cm (L X W X H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    * Cooling Capacity: 750W

    * Active cooling

    * Temperature stability: ±0.3°C

    * Temperature control range: 5°C ~35°C

    * Refrigerant: R-134a

    * Compact, portable design and quiet operation

    * High efficiency compressor

    * Top mounted water fill port

    * Integrated alarm functions

    * Low maintenance and high reliability

    * 50Hz/60Hz dual-frequency compatible available

    * Optional dual water inlet & outlet       

    Optional Items

                  

     Heater


                   

    Filter


                  

     US standard plug / EN standard plug


    Product Details
    Industrial Water Chiller CW-5000 User-friendly Control Panel
                                           

    User-friendly control panel


    The temperature controller offers high precision temperature control of ±0.3°C and two user-adjustable temperature control modes - constant temperature mode and intelligent control mode. 


    Industrial Water Chiller CW-5000 Easy-to-read water level indicator
                                           

    Easy-to-read water level indicator


    The water level indicator has 3 color areas - yellow, green and red.

    Yellow area - high water level.

    Green area - normal water level.

    Red area - low water level.


    Industrial Water Chiller CW-5000 Dust-proof filter
                                           

    Dust-proof filter


    Integrated with the grill of the side panels, easy mounting and removal.

    Ventilation Distance


    Industrial Water Chiller CW-5000 Ventilation Distance

    Certificate
    Industrial Water Chiller CW-5000 Certificate
    Product Working Principle


    Industrial Water Chiller CW-5000 Product Working Principle

    FAQ
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial water chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the industrial water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.


    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect