TEYU mini industrial chiller CW-3000 is a basic passive cooling solution suitable for ≤80W CO2 laser engraver powered by DC glass tube. Featuring a heat dissipation capacity of 50W/℃ and a 9L reservoir, this small chiller can radiate the heat from the laser tube very effectively. It's designed with a high-speed fan inside without compressor to reach heat exchange in a simple structure with high reliability.

Air cooled industrial chiller CW-3000 is compact and reliable, the dimension is only 49X27X38cm (L X W X H), which provides efficient cooling while saving a lot of space for laser users. Integrated top mount handle for easy portability. The digital temperature display is able to indicate temperature and alarm codes. With excellent heat dissipation capability and cost-effective price, portable CW 3000 industrial chiller has become the favorite of ≤80W CO2 laser engraving machine users.

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    Mini Industrial Chiller CW-3000 for CO2 Laser Engraving Machine

    Model: CW-3000

    Machine Size: 49X27X38cm (L X W X H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    ModelCW-3000TGTYCW-3000DGTYCW-3000TKTYCW-3000DKTY
    VoltageAC 1P 220~240VAC 1P 110VAC 1P 220~240VAC 1P 110V
    Frequency50/60Hz60Hz50/60Hz60Hz
    Current0.4~0.7A0.4~0.9A0.3~0.6A0.3~0.8A

    Max. power consumption

    0.07kW0.11kW
    Radiating capacity50W/℃

    Max. pump pressure

    1bar7bar

    Max. pump flow

    10L/min2L/min
    ProtectionFlow alarm
    Tank capacity9L
    Inlet and outletOD 10mm Barbed connector8mm Fast connector
    N.W.9Kg11Kg
    G.W.11Kg13Kg
    Dimension49X27X38cm (L X W X H)
    Package dimension55X34X43cm (L X W X H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    * Heat dissipation capacity: 50W/℃, meaning it can absorb 50W of heat by rising 1°C of water temperature;

    * Passive cooling, no refrigerant

    * High speed fan                                      

    * 9L reservoir

    * Digital temperature display

    * Built-in alarm functions

    * Easy operation and space-saving                                 

    * Low energy and environmental

    Optional Items

                  

     Heater


                   

    Filter


                  

     US standard plug / EN standard plug


    Product Details
    Mini Industrial Chiller CW-3000 High speed fan
                                           

    High speed fan


    The high speed fan is installed to ensure high cooling performance.

    Mini Industrial Chiller CW-3000 Integrated top mounted handle
                                           

    Integrated top mounted handle


    The firm handles are mounted on top for easy mobility.

    Mini Industrial Chiller CW-3000 Digital temperature display
                                           

    Digital temperature display


    The digital temperature display is able to indicate water temperature and alarm codes. 

    Ventilation Distance

    Mini industrial chiller CW-3000 Ventilation Distance

    Certificate
    Industrial chiller CW-3000 Certificate
    Product Working Principle

    Industrial chiller CW-3000 Product Working Principle

    FAQ
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the industrial chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.


    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect