TEYU Kua hangaia te pouaka whakamatao ahumahi CW-6200BNPTY-UL mō ngā tono whakamatao tukanga ahumahi e hiahia ana ki te whakahaere pāmahana pono me te pumau mahi mo te wa roa. E tuku ana i te kaha whakamatao 5100W me te pumau pāmahana ±0.5°C, kua whakamatautauria motuhake e te SGS ki ngā paerewa UL me te CSA, ā, kua hangaia hei tautoko i ngā tono ahumahi o Amerika Te Raki.


He rite ki ngā aratau whakahaere pāmahana atamai, te whakawhitiwhiti kōrero RS-485 Modbus RTU, he pouaka hononga hiko hiri, me te tiakitanga maha-taumata, ka taea te whakauru ngāwari ki te TEYU CW-6200BNPTY-UL me te whānuitanga o ngā taputapu ahumahi. He tino pai mō ngā taputapu mīhini CNC, ngā pūnaha taiaho CO₂, ngā taputapu tā, ngā mīhini tākai, me ētahi atu tono whakamatao tukanga tonu.

Product characteristics

Product parameters

TauiraCW-6200BNPTY-UL NgaohikoAC 1P 220~240V
Auautanga 60Hz Ināianei3.4~10.4A
Te whakapaunga mana mōrahi 2.3kW Te kaha whakamatao ingoa 17401Btu/h
Mana pūhiko 1.39kW 5.1kW
1.89HP 4384Kcal/h
Mana papu 0.75kW Te pēhanga papu mōrahi 5 pae
Rere kua whakatauria 33L/min Pūmahana WhakamataoR-32
Te tika ±0.5℃ Kaiwhakaiti Āpitirei
Te kaha o te tāke22L Te tomokanga me te putanga Rp1/2"
N.W. 76kg Ahu 67 × 47 × 90cm (L × W × H)
G.W. 87kg Ahu mōkihi 73 × 57 × 105cm (R × W × T)

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Smart Communication: RS-485 Modbus RTU simplifies MES and automation integration.
Smart Communication: RS-485 Modbus RTU enables seamless MES and automation integration.
Precise temperature control
±0.5°C precision helps maintain stable laser performance during continuous operation.
Easy water level monitoring
Three-color indicator clearly shows high, normal, and low water levels.
Sealed electrical junction box
Enhances wiring safety and installation flexibility in industrial environments.
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Kainga   |     Hua       |     SGS & UL Chiller       |     Rongoa whakamahana     |     Kamupene      |    Rauemi       |      Te oranga tonutanga
Mana pupuri © 2026 TEYU S&A Whakamatao | Mahere Pae Kaupapahere tūmataiti
Whakapā mai
email
Whakapa atu ki te Ratonga Kaihoko
Whakapā mai
email
whakakore
Customer service
detect