TEYU CW-6200BNPTY-UL industrial chiller e etselitsoe lits'ebetso tsa ho pholisa tsa ts'ebetso ea indasteri tse hlokang taolo e tšepahalang ea mocheso le botsitso ba ts'ebetso ea nako e telele. E fana ka bokhoni ba ho pholisa ba 5100W ka botsitso ba mocheso oa ±0.5°C, e lekoa ka boikemelo ke litekanyetso tsa SGS ho ea ho UL le CSA mme e hahiloe ho ts'ehetsa lits'ebetso tsa indasteri tsa Amerika Leboea.


E hlomelitsoe ka mekhoa e bohlale ea taolo ea mocheso, puisano ea RS-485 Modbus RTU, lebokose la motlakase le koetsoeng, le tšireletso ea maemo a mangata, TEYU CW-6200BNPTY-UL e hokahana habonolo le mefuta e mengata ea lisebelisoa tsa indasteri. E loketse hantle lisebelisoa tsa mochini oa CNC, litsamaiso tsa laser tsa CO₂, lisebelisoa tsa khatiso, mechini ea ho paka, le lits'ebetso tse ling tse tsoelang pele tsa ho pholisa.

Product characteristics

Product parameters

MohlalaCW-6200BNPTY-UL Palo ea li-voltsAC 1P 220~240V
Maqhubu 60Hz Hona joale3.4~10.4A
Tšebeliso e phahameng ka ho fetisisa ea matla 2.3kW Bokhoni ba ho pholisa bo ikgethang 17401Btu/h
Matla a konpresser 1.39kW 5.1kW
1.89HP 4384Kcal/h
Matla a pompo 0.75kW Khatello e phahameng ea pompo Bara e 5
Phallo e lekantsoe 33L/motsotso SehatsetsingR-32
Ho nepahala ± 0.5℃ Sefokotsi Mothapo oa mali
Bokhoni ba tanka22L Monyako le sehokelo Rp1/2"
N.W. 76kg Tekanyo 67 × 47 × 90cm (L × W × H)
G.W. 87kg Tekanyo ea sephutheloana 73 × 57 × 105cm(L × Bophara × Bophahamo)

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Smart Communication: RS-485 Modbus RTU simplifies MES and automation integration.
Smart Communication: RS-485 Modbus RTU enables seamless MES and automation integration.
Precise temperature control
±0.5°C precision helps maintain stable laser performance during continuous operation.
Easy water level monitoring
Three-color indicator clearly shows high, normal, and low water levels.
Sealed electrical junction box
Enhances wiring safety and installation flexibility in industrial environments.
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Lehae   |     Lihlahisoa       |     SGS & UL Chiller       |     Tharollo ea ho Pholisa     |     Khampani      |    Mohlodi       |      Moshoelella
Tokelo ea Mongoli © 2026 TEYU S&A Chiller | 'Mapa oa Sebaka Leano la Lekunutu
Iteanye le rona
email
Ikopanye le ts'ebeletso ea bareki
Iteanye le rona
email
hlakola
Customer service
detect