Chiller tal-Proċess Industrijali ttestjat mill-SGS CW-6200BNPTY-UL

Chiller tal-Proċess Konformi mal-UL u s-CSA għal Applikazzjonijiet CNC, Laser, u Industrijali

TEYU Iċ-chiller industrijali CW-6200BNPTY-UL huwa ddisinjat għal applikazzjonijiet ta' tkessiħ ta' proċessi industrijali li jeħtieġu kontroll affidabbli tat-temperatura u stabbiltà operattiva fit-tul. B'kapaċità ta' tkessiħ ta' 5100W b'stabbiltà tat-temperatura ta' ±0.5°C, huwa ttestjat b'mod indipendenti minn SGS skont l-istandards UL & CSA u mibni biex jappoġġja applikazzjonijiet industrijali tal-Amerika ta' Fuq.


Mgħammar b'modi intelliġenti ta' kontroll tat-temperatura, komunikazzjoni RS-485 Modbus RTU, kaxxa ta' junction elettrika ssiġillata, u protezzjoni b'ħafna livelli, TEYU CW-6200BNPTY-UL jintegra faċilment ma' firxa wiesgħa ta' tagħmir industrijali. Huwa adattat sew għal għodod tal-magni CNC, sistemi tal-lejżer CO₂, tagħmir tal-istampar, makkinarju tal-ippakkjar, u applikazzjonijiet oħra ta' tkessiħ ta' proċess kontinwu.

Product characteristics

Product parameters

MudellCW-6200BNPTY-UL VultaġġAC 1P 220~240V
Frekwenza 60Hz Kurrenti3.4~10.4A
Konsum massimu tal-enerġija 2.3kW Kapaċità nominali tat-tkessiħ 17401Btu/siegħa
Qawwa tal-kompressur 1.39kW 5.1kW
1.89HP 4384Kcal/siegħa
Qawwa tal-pompa 0.75kW Pressjoni massima tal-pompa 5 bars
Fluss nominali 33L/min RefriġerantR-32
Preċiżjoni ±0.5℃ Tnaqqis Kapillari
Kapaċità tat-tank22L Dħul u ħruġ Rp1/2"
N.W. 76kg Dimensjoni 67 × 47 × 90cm (L × W × H)
G.W. 87kg Dimensjoni tal-pakkett 73 × 57 × 105 ċm (T × W × G)

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Smart Communication: RS-485 Modbus RTU simplifies MES and automation integration.
Smart Communication: RS-485 Modbus RTU enables seamless MES and automation integration.
Precise temperature control
±0.5°C precision helps maintain stable laser performance during continuous operation.
Easy water level monitoring
Three-color indicator clearly shows high, normal, and low water levels.
Sealed electrical junction box
Enhances wiring safety and installation flexibility in industrial environments.
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Dar   |     Prodotti       |     SGS & UL Chiller       |     Soluzzjoni tat-Tkessiħ     |     Kumpanija      |    Riżorsa       |      Sostenibbiltà
Drittijiet tal-awtur © 2026 TEYU S&A Chiller | Mappa tas-sit Politika tal-privatezza
Ikkuntatjana
email
Ikkuntattja servizz tal-konsumatur
Ikkuntatjana
email
Ikkanċella
Customer service
detect