loading
4U Rack Mount Water Chiller RMUP-300 for UV Laser Ultrafast Laser
4U Rack Mount Water Chiller RMUP-300 for UV Laser Ultrafast Laser
4U Rack Mount Water Chiller RMUP-300 for UV Laser Ultrafast Laser
4U Rack Mount Water Chiller RMUP-300 for UV Laser Ultrafast Laser
4U Rack Mount Water Chiller RMUP-300 for UV Laser Ultrafast Laser
4U Rack Mount Water Chiller RMUP-300 for UV Laser Ultrafast Laser
4U Rack Mount Water Chiller RMUP-300 for UV Laser Ultrafast Laser
4U Rack Mount Water Chiller RMUP-300 for UV Laser Ultrafast Laser

4U Rack Mount Water Chiller RMUP-300 for UV Laser Ultrafast Laser

TEYU rack mount water chiller RMUP-300 is only 4U tall and ideally suited for 3W-5W UV laser and ultrafast laser. It delivers extremely precise cooling of ±0.1°C stability with PID control technology and a cooling capacity of up to 380W. Being extremely temperature stable, RMUP-300 water chiller can satisfy your demanding laser processes.

Rack mount water chiller RMUP-300 incorporates standard features like highly durable water pump, high performance cooling fan and integrated front handles which allow for easy mobility. The water fill port and drain port are mounted in the front, which is very convenient to use. The refrigerant used complies with environmental standards. Small, lightweight, ultra-precise, space-saving, mini dimension for superior performance, RMUP-300 water chiller can realize all your imagination of a small laser cooling unit.

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    4U Rack Mount Water Chiller RMUP-300 for UV Laser Ultrafast Laser

    Model: RMUP-300

    Machine Size: 49X48X18cm (L X W X H) 4U

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    MedelRMUP-300AHTYRMUP-300BHTY
    VoltageAC 1P 220-240VAC 1P 220-240V
    Frequency50Hz60Hz
    Current0.5~5A0.5~4.8A

    Max. power consumption

    0.84kW0.9kW


    Compressor power

    0.21kW0.27kW
    0.29HP0.36HP



    Nominal cooling capacity

    1296Btu/h
    0.38kW
    326Kcal/h
    RefrigerantR-134a
    Precision±0.1℃
    ReducerCapillary
    Pump power0.05kW
    Tank capacity3L
    Inlet and outletRp1/2"

    Max. pump pressure

    1.2bar
    Max. pump flow13L/min
    N.W.19Kg
    G.W.21Kg
    Dimension49X48X18cm (L X W X H) 4U
    Package dimension59X53X26cm (L X W X H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    Intelligent functions

    * Low tank water level detecting

    * Low water flow rate detecting

    * Over water temperature detecting

    * Heating of the coolant water at low ambient temperature


    Self-check display

    * 12 types of alarm codes

    Easy routine maintenance

    * Toolless maintenance of dustproof filter screen

    * Quick-replaceable optional water filter


    Communication function

    * Equipped with RS485 Modbus RTU protocol

    Optional Items

                  

     Heater


                   

    Filter


                  

     US standard plug / EN standard plug


    Product Details
    Rack Mount Water Chiller RMUP-300 Digital temperature controller

                                            Digital temperature controller


    The T-801B temperature controller offers high precision temperature control of ±0.1°C. 

    Rack Mount Water Chiller RMUP-300 front mounted water fill port and drain port

                                            Front mounted water fill port and drain port


    The water fill port and drain port are mounted in the front for easy water filling and draining.

    Water Chiller RMUP-300 Modbus RS485 communication port

                                            Modbus RS485 communication port


    The RS485 communication port enables communication with the laser system.
    Certificate
    Rack Mount Cooling System RMUP-300 Certificate
    Product Working Principle

    Rack Mount Cooling System RMUP-300 Product Working Principle

    FAQ
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the water chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.


    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect