Njengoko ubushushu behlobo buguquguquka,
i-industrial chillers
—izixhobo zokupholisa ezibalulekileyo kwizicelo ezininzi zamashishini—dlala indima ebalulekileyo ekuqinisekiseni imigca yemveliso egudileyo. Kwiindawo ezishushu, i-industrial chillers inokuqalisa imisebenzi eyahlukeneyo yokuzikhusela, njenge-alamu ye-E1 ye-ultrahigh yeqondo lokushisa, ukuqinisekisa imveliso ekhuselekileyo. Esi sikhokelo siya kukunceda uxazulule i-alamu ye-E1 kwi-TEYU S&A's industrial chillers:
Unobangela woku-1: Ubushushu obuphezulu be-Ambient
Cofa i “▶” iqhosha kwisilawuli ukufaka imo yokubonisa imenyu kwaye ujonge ubushushu obuboniswe ngu t1. Ukuba ikufuphi 40°C, ubushushu be-ambient buphezulu kakhulu. Kunconywa ukugcina ubushushu begumbi phakathi kwama-20-30°C ukuqinisekisa ukuba i-industrial chiller isebenza ngokuqhelekileyo.
Ukuba amaqondo obushushu aphezulu eworkshop achaphazela i-industrial chiller, cinga ukusebenzisa iindlela zokupholisa ngokomzimba ezifana neefeni ezipholileyo ngamanzi okanye iikhethini zamanzi ukunciphisa ubushushu.
Unobangela onokwenzeka wesi-2: Ukungena komoya okungonelanga kwi-Industrial Chiller
Khangela ukuba kukho indawo eyaneleyo ejikeleze indawo yokungenisa umoya kunye nendawo yokuphuma yesibandisi seshishini. I-air outlet kufuneka ibe ubuncinane i-1.5 yeemitha ukusuka kuyo nayiphi na imiqobo, kwaye i-air inlet kufuneka ibe ubuncinane imitha eyi-1, iqinisekise ukuchithwa kobushushu.
Unobangela wesi-3 onokwenzeka: Ukuqokelelwa kothuli olunzima Ngaphakathi kwi-Industrial Chiller
Ehlotyeni, ii-chillers zamashishini zisetyenziswa rhoqo, zibangela ukuba uthuli luqokelele ngokulula kwi-gauzes yokucoca kunye ne-condensers. Zicoce rhoqo kwaye usebenzise umpu womoya ukuvuthela uthuli olusuka kumaphiko econdenser. Oku kuya kuphucula ngempumelelo i-industrial chiller yokuphelisa ubushushu. (Okukhona usiba makhulu amandla e-industrial chiller, kokukhona kufuneka ucoce rhoqo.)
Unobangela wesi-4: Isivamvo sobushushu segumbi esinempazamo
Vavanya isivamvo sobushushu begumbi ngokusibeka emanzini ngobushushu obaziwayo (kucetyisiwe 30°C) kwaye khangela ukuba iqondo lokushisa elibonisiweyo lihambelana neqondo lobushushu langempela. Ukuba kukho ukungafani, i-sensor iphosakele (i-sensor yeqondo lokushisa eliphosakeleyo lingabangela ikhowudi yephutha ye-E6). Kule meko, i-sensor kufuneka itshintshwe ukuze kuqinisekiswe ukuba i-chiller ye-industrial iyakwazi ukubona ngokuchanekileyo ubushushu begumbi kwaye ilungelelanise ngokufanelekileyo.
Ukuba usenemibuzo malunga nokugcinwa okanye ukulungisa ingxaki kwi-TEYU S&A's industrial chillers, nceda ucofe
Chiller Troubleshooting
, okanye uqhagamshelane neqela lethu emva-intengiso kwi
service@teyuchiller.com
![How to Solve the E1 Ultrahigh Room Temperature Alarm Fault on Industrial Chillers?]()