loading
Water Chiller CWFL-1000 for 500W-1kW Fiber Laser Cutting Welding Machine
Water Chiller CWFL-1000 for 500W-1kW Fiber Laser Cutting Welding Machine
Water Chiller CWFL-1000 for 500W-1kW Fiber Laser Cutting Welding Machine
Water Chiller CWFL-1000 for 500W-1kW Fiber Laser Cutting Welding Machine
Water Chiller CWFL-1000 for 500W-1kW Fiber Laser Cutting Welding Machine
Water Chiller CWFL-1000 for 500W-1kW Fiber Laser Cutting Welding Machine
Water Chiller CWFL-1000 for 500W-1kW Fiber Laser Cutting Welding Machine
Water Chiller CWFL-1000 for 500W-1kW Fiber Laser Cutting Welding Machine

Water Chiller CWFL-1000 for 500W-1kW Fiber Laser Cutting Welding Machine

TEYU CWFL-1000 water chiller is a high-efficiency dual-circuit cooling solution designed for fiber laser cutting and welding machines up to 1kW. Each circuit operates independently—one for cooling the fiber laser and the other for cooling the optics—eliminating the need for two separate chillers.

TEYU CWFL-1000 water chiller is built with components that comply with CE, REACH, and RoHS standards. It provides precise cooling with ±0.5°C stability, helping to extend the lifespan and enhance the performance of your fiber laser system. Additionally, multiple built-in alarms protect both the laser chiller and the laser equipment. Four caster wheels offer easy mobility, providing unmatched flexibility. The CWFL-1000 chiller is the ideal cooling solution for your 500W-1000W laser cutter or welder.

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    Water Chiller CWFL-1000 for 500W-1kW Fiber Laser Cutting Welding Machine

    Model: CWFL-1000

    Machine Size: 70 X 47 X 89cm (LX W X H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    Model CWFL-1000ANPTY CWFL-1000BNPTY
    Voltage AC 1P 220-240V AC 1P 220-2400V
    Frequency 50Hz 60Hz
    Current 2.5~13.5A 3.9~15.5A

    Max. power consumption

    2.53kW 3.14kW

    Heater power

    0.55kW+0.6kW
    Precision ±0.5℃
    Reducer Capillary
    Pump power 0.37kW 0.75kW
    Tank capacity 14L
    Inlet and outlet Rp1/2"+Rp1/2"

    Max. pump pressure

    3.6bar 5.3bar
    Rated flow 2L/min + >12L/min
    N.W. 63Kg 66Kg
    G.W. 75Kg 76Kg
    Dimension 70 X 47 X 89cm (LX W X H)
    Package dimension 73 X 56 X 105cm (LX W X H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    * Dual cooling circuit

    * Active cooling

    * Temperature stability: ±0.5°C

    * Temperature control range: 5°C ~35°C

    * Refrigerant: R-410A

    * User-friendly controller interface

    * Integrated alarm functions

    * Back mounted fill port and visual water level

    * Optimized for high performance at low temperatures

    * Ready for immediate use

    Optional Items

                  

     Heater

     

                   

    Filter

     

                  

     US standard plug / EN standard plug

     

    Product Details
    Process Water Chiller CWFL-1000 temperature control
                                           

    Dual temperature control

     

    The intelligent control panel offers two independent temperature control systems. One is for controlling the temperature of the fiber laser and the other is for controlling the temperature of the optics.

    TEYU 1000 Laser Welding Chiller Water Inlet and Water Outlet
                                           

    Dual water inlet and water outlet

     

    Water inlets and water outlets are made from stainless steel to prevent potential corrosion or water leakage.

    1000W Laser Engraver Chiller Caster wheels
                                           

    Caster wheels for easy mobility

     

    Four caster wheels offer easy mobility and unmatched flexibility.

    Ventilation Distance

    Industrial Water Chiller Ventilation Distance

    Certificate
    TEYU Laser Water Chiller Certificate
    Product Working Principle

    Laser Cutting Machine Chiller CWFL-1000 Working Principle

    FAQ
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the water chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect