loading
Ultrafast Laser & UV Laser Chiller
VR
Product Introduction
Small Industrial Chiller CWUP-10 for Ultrafast Laser UV Laser ±0.1°C Precision

Model: CWUP-10

Machine Size: 58X29X52cm  (L X W X H)

Warranty: 2 years

Standard: CE, REACH and RoHS

Product Parameters
ModelCWUP-10AITYCWUP-10BITY
VoltageAC 1P 220-240VAC 1P 220~240V
Frequency50Hz60Hz
Current0.6~5.6A0.6~5.6A
Max. power consumption1.02kW1.04kW


Compressor power

0.37kW0.39kW
0.49HP0.53HP



Nominal cooling capacity

2559Btu/h
0.75kW
644Kcal/h
RefrigerantR-134a
Precision±0.1℃
ReducerCapillary
Pump power0.09kW
Tank capacity6L
Inlet and outletRp1/2”
Max. pump pressure2.5bar
Max. pump flow15L/min
N.W24Kg
G.W27Kg
Dimension58X29X52cm  (L X W X H)
Package dimension65X36X56cm (L X W X H)

The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

Product Features

Intelligent functions

* Low tank water level detecting

* Low water flow rate detecting

* Over water temperature detecting

* Heating of the coolant water at low ambient temperature


Self-check display

* 12 types of alarm codes

Easy routine maintenance

* Toolless maintenance of dustproof filter screen

* Quick-replaceable optional water filter


Communication function

* Equipped with RS485 Modbus RTU protocol

Optional Items

              

 Heater


               

Filter


              

 US standard plug / EN standard plug


Product Details
Small Industrial Chiller CWUP-10 Digital temperature controller

                                        Digital temperature controller


The T-801B temperature controller offers high precision temperature control of ±0.1°C. 

Small Industrial Chiller CWUP-10 Easy-to-read water level indicator

                                        Easy-to-read water level indicator


The water level indicator has 3 color areas - yellow, green and red.

Yellow area - high water level.

Green area - normal water level.

Red area - low water level.

Small Industrial Chiller CWUP-10 Modbus RS485 communication port

                                        Modbus RS485 communication port


The RS485 communication port enables communication with the laser system.
Ventilation Distance

TEYU Small Industrial Chiller CWUP-10 Ventilation Distance

Certificate
TEYU Small Industrial Chiller CWUP-10 Certificate
Product Working Principle

TEYU Small Industrial Chiller CWUP-10 Product Working Principle

FAQ
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
What is the ideal room temperature for the industrial chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team ([email protected]) first.


Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --

If You Have More Questions, Write To Us

Just leave your email or phone number on the contact form so we can provide you with more services!

Send your inquiry

Choose a different language
English
العربية
Deutsch
Español
français
italiano
日本語
한국어
Português
русский
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Ελληνικά
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
Magyar
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Latin
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda‎
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
Nederlands
norsk
Chicheŵa
ਪੰਜਾਬੀ
Polski
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
ภาษาไทย
Pilipino
Türkçe
Українська
اردو
O'zbek
Tiếng Việt
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English