loading
Portable Industrial Chiller CWUP-10 for Ultrafast Laser UV Laser ±0.1°C Precision
Portable Industrial Chiller CWUP-10 for Ultrafast Laser UV Laser ±0.1°C Precision
Portable Industrial Chiller CWUP-10 for Ultrafast Laser UV Laser ±0.1°C Precision
Portable Industrial Chiller CWUP-10 for Ultrafast Laser UV Laser ±0.1°C Precision
Portable Industrial Chiller CWUP-10 for Ultrafast Laser UV Laser ±0.1°C Precision
Portable Industrial Chiller CWUP-10 for Ultrafast Laser UV Laser ±0.1°C Precision
Portable Industrial Chiller CWUP-10 for Ultrafast Laser UV Laser ±0.1°C Precision
Portable Industrial Chiller CWUP-10 for Ultrafast Laser UV Laser ±0.1°C Precision

Portable Industrial Chiller CWUP-10 for Ultrafast Laser UV Laser ±0.1°C Precision

TEYU portable industrial chiller CWUP-10 is specifically designed for ultrafast laser and UV laser. It delivers superior temperature control of ±0.1°C with PID control technology. A compressor refrigeration circuit with properly designed pipeline arrangement avoids the generation of bubble to reduce the impact to the lasers. Small as its dimension of 58X29X52cm, its temperature control ability doesn’t compromise. 

What makes CWUP-10 Ultrafast UV laser chiller even unique is that it incorporates the RS485 Modbus communication function, providing higher level of communication between the chiller and the laser system. Easy-to-read water level indicator, digital temperature controller and 12 built-in alarm codes, all reflect its user-friendly. Lightweight, portable and easy to maintain, making laser chiller CWUP-10 widely used in cooling ultrafast laser and UV laser.

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    Small Industrial Chiller CWUP-10 for Ultrafast Laser UV Laser ±0.1°C Precision

    Model: CWUP-10

    Machine Size: 58X29X52cm (L X W X H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    ModelCWUP-10AITYCWUP-10BITY
    VoltageAC 1P 220-240VAC 1P 220~240V
    Frequency50Hz60Hz
    Current0.6~5.3A0.6~5.3A
    Max. power consumption1.04kW1.04kW


    Compressor power

    0.39kW0.39kW
    0.52HP0.53HP



    Nominal cooling capacity

    2559Btu/h
    0.75kW
    644Kcal/h
    RefrigerantR-134a
    Precision±0.1℃
    ReducerCapillary
    Pump power0.09kW
    Tank capacity6L
    Inlet and outletRp1/2”
    Max. pump pressure2.5bar
    Max. pump flow15L/min
    N.W.24Kg
    G.W.27Kg
    Dimension58X29X52cm (L X W X H)
    Package dimension65X36X56cm (L X W X H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    Intelligent functions

    * Low tank water level detecting

    * Low water flow rate detecting

    * Over water temperature detecting

    * Heating of the coolant water at low ambient temperature


    Self-check display

    * 12 types of alarm codes

    Easy routine maintenance

    * Toolless maintenance of dustproof filter screen

    * Quick-replaceable optional water filter


    Communication function

    * Equipped with RS485 Modbus RTU protocol

    Optional Items

                  

     Heater


                   

    Filter


                  

     US standard plug / EN standard plug


    Product Details
    Small Industrial Chiller CWUP-10 Digital temperature controller

                                            Digital temperature controller


    The T-801B temperature controller offers high precision temperature control of ±0.1°C. 

    Small Industrial Chiller CWUP-10 Easy-to-read water level indicator

                                            Easy-to-read water level indicator


    The water level indicator has 3 color areas - yellow, green and red.

    Yellow area - high water level.

    Green area - normal water level.

    Red area - low water level.

    Small Industrial Chiller CWUP-10 Modbus RS485 communication port

                                            Modbus RS485 communication port


    The RS485 communication port enables communication with the laser system.
    Ventilation Distance

    TEYU Small Industrial Chiller CWUP-10 Ventilation Distance

    Certificate
    TEYU Small Industrial Chiller CWUP-10 Certificate
    Product Working Principle

    TEYU Small Industrial Chiller CWUP-10 Product Working Principle

    FAQ
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the industrial chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.


    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect