loading
Portable Water Chiller CWUP-30 for Ultrafast Laser UV Laser ±0.1°C Precision Modbus 485 Communication
Portable Water Chiller CWUP-30 for Ultrafast Laser UV Laser ±0.1°C Precision Modbus 485 Communication
Portable Water Chiller CWUP-30 for Ultrafast Laser UV Laser ±0.1°C Precision Modbus 485 Communication
Portable Water Chiller CWUP-30 for Ultrafast Laser UV Laser ±0.1°C Precision Modbus 485 Communication
Portable Water Chiller CWUP-30 for Ultrafast Laser UV Laser ±0.1°C Precision Modbus 485 Communication
Portable Water Chiller CWUP-30 for Ultrafast Laser UV Laser ±0.1°C Precision Modbus 485 Communication
Portable Water Chiller CWUP-30 for Ultrafast Laser UV Laser ±0.1°C Precision Modbus 485 Communication
Portable Water Chiller CWUP-30 for Ultrafast Laser UV Laser ±0.1°C Precision Modbus 485 Communication

Portable Water Chiller CWUP-30 for Ultrafast Laser UV Laser ±0.1°C Precision Modbus 485 Communication

Our expertise in high precision cooling technology translates into air cooled industrial chiller CWUP-30. This laser machining cooling unit may be simple in design yet it delivers precise cooling featuring ±0.1°C stability with PID control technology and steady flow of chilled water for your ultrafast lasers and UV lasers. Designed with Modbus 485 function to provide effective communication between the chiller and laser system. 

Completely self-contained, TEYU CWUP-30 laser water chiller combines a high-efficiency compressor and a durable fan-cooled condenser and is suitable for purified water, distilled water or deionised water. Designed with multiple built-in alarm functions and an intelligent digital temperature controller. Easy-fill port is mounted on top while 4 caster wheels are easy for mobility.

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    Portable Water Chiller CWUP-30 for Ultrafast Laser UV Laser ±0.1°C Precision Modbus-485

    Model: CWUP-30

    Machine Size: 59X38X74cm (L X W X H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    Model CWUP-30ANTY CWUP-30BNTY
    Voltage AC 1P 220-240V AC 1P 220-240V
    Frequency 50Hz 60Hz
    Current 2.3~9A 2.1~8.9A

    Max. power consumption

    1.9kW 1.91kW


    Compressor power

    0.87kW 0.88kW
    1.17HP 1.18HP


    Nominal cooling capacity

    8188Btu/h
    2.4kW
    2063Kcal/h
    Refrigerant R-410A
    Precision ±0.1℃
    Reducer Capillary
    Pump power 0.37kW
    Tank capacity 10L
    Inlet and outlet Rp1/2"

    Max. pump pressure

    2.7bar
    Max. pump flow 75L/min
    N.W. 52Kg 55Kg
    G.W. 58Kg 61Kg
    Dimension 59X38X74cm (L X W X H)
    Package dimension 66X48X92cm (L X W X H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    Intelligent functions

    * Low tank water level detecting

    * Low water flow rate detecting

    * Over water temperature detecting

    * Heating of the coolant water at low ambient temperature

    Self-check display

    * 12 types of alarm codes

    Easy routine maintenance

    * Toolless maintenance of dustproof filter screen

    * Quick-replaceable optional water filter

    Communication function

    * Equipped with RS485 Modbus RTU protocol

    Optional Items

                  

     Heater

     

                   

    Filter

     

                  

     US standard plug / EN standard plug

     

    Product Details
    Ultrafast UV Laser Chiller CWUP-30 Digital temperature controller

                                            Digital temperature controller

     

    The T-801B temperature controller offers high precision temperature control of ±0.1°C. 

    Ultrafast UV Laser Chiller CWUP-30 Easy-to-read water level indicator

                                            Easy-to-read water level indicator

     

    The water level indicator has 3 color areas - yellow, green and red.

    Yellow area - high water level.

    Green area - normal water level.

    Red area - low water level.

    Ultrafast UV Laser Chiller CWUP-30 Modbus RS485 communication

                                            Modbus RS485 communication port

     

    The RS485 communication port enables communication with the laser system.
    Ventilation Distance

    Ultrafast UV Laser Chiller CWUP-30 Ventilation Distance

    Certificate
    Ultrafast UV Laser Chiller CWUP-30 Certificate
    Product Working Principle

    Ultrafast UV Laser Chiller CWUP-30 Product Working Principle

    FAQ
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the industrial chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect