TEYU RMFL-2000 is a rack mount industrial chiller designed for cooling up to 2KW handheld laser welding cleaning machine and mountable in a 19-inch rack. Because of the rack mount design, industrial water cooling system RMFL-2000 allows the stacking of related device, indicating a high level of flexibility and mobility. Temperature stability is ±0.5°C and the temperature control range is from 5°C to 35°C. 

Rack mount laser cooler RMFL-2000 comes with a high-performance water pump. Dual temperature control to realize an industrial chiller to cool the fiber laser and the optics/laser gun at the same time. The water fill port and drain port are mounted on the front together with a thoughtful water level check. Intelligent digital control panel displays the temperature and built-in alarm codes. High level of flexibility and mobility, making this active cooling water chiller the perfect cooling solution for handheld laser.

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    Rack Mount Cooler RMFL-2000 for 2KW Handheld Laser Welding System

    Model: RMFL-2000

    Machine Size: 77 X 48 X 43cm  (L X W X H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    Model RMFL-2000ANT03TY RMFL-2000BNT03TY
    Voltage AC 1P 220-240V AC 1P 220-240V
    Frequency 50Hz 60Hz
    Current 1.5~12.1A 1.5~14.7A
    Max. power consumption 2.81kW 3.27kW

    Compressor power

    1.36kW 1.77kW
    1.82HP 2.37HP
    Refrigerant R-32/R-410A R-410A
    Precision ±0.5℃
    Reducer Capillary
    Pump power 0.32kW
    Tank capacity 16L
    Inlet and outlet Φ6+Φ12 Fast connector
    Max. pump pressure 4bar
    Rated flow 2L/min+>15L/min 
    N.W. 51Kg
    G.W. 61Kg
    Dimension 77x48x43cm(LxWxH)
    Package dimension 88x58x61cm(LxWxH)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    * Rack mount design

    * Dual cooling circuit

    * Active cooling

    * Temperature stability: ±0.5°C

    * Temperature control range: 5°C ~35°C

    * Refrigerant: R-32/R-410A

    * Intelligent digital control panel

    * Integrated alarm functions

    * Front mounted water fill port and drain port

    * Integrated front handles

    * High level of flexibility and mobility

    Optional Items

                  

     Heater

     

                   

    Filter

     

                  

     US standard plug / EN standard plug

     

    Product Details
    TEYU RMFL-2000 Laser Chiller Temperature Controller T-506E
                                           

    Dual temperature control

     

    Intelligent temperature controller. Controlling the temperature of the fiber laser and optics at the same time.

    TEYU laser chiller front mounted water fill port and drain port
                                           

    Front mounted water fill port and drain port

     

    The water fill port and drain port are mounted in the front for easy water filling and draining.

    TEYU RMFL-2000 Laser Chiller Integrated Front Handles
                                           

    Integrated front handles

     

    The front-mounted handles help move the chiller very easily.

    Certificate
    TEYU Industrial Water Chiller Certificate
    Product Working Principle

    TEYU Laser Chiller RMFL-2000 Working Principle

    FAQ
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the water chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect