TEYU air-cooled water chiller CWFL-2000 is made specifically by TEYU industrial chiller manufacturer to control the temperature of fiber laser metal cutter welder up to 2kW. CWFL-2000 chiller features two channels in one housing, targeting two areas in the fiber laser system - the fiber laser and the optics. This dual channel design reduces the water chiller footprint to a great extent comparing with the two-single-chiller arrangement. 

CWFL-2000 industrial fiber laser cooling system is designed to operate under indoor conditions and can be easily serviced by taking away the side housings. It comes equipped with an easy-to-read water level check and easy-fill port, making water adding quite convenient. Multiple alarm devices provide further protection, making the operation of industrial chiller and laser equipment more stable and reliable.

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    Air Cooled Water Chiller System CWFL-2000 for 2KW Fiber Laser Metal Cutter

    Model: CWFL-2000

    Machine Size: 70 X 47 X 89cm (L X W X H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

     

    Product Parameters
    Model CWFL-2000ANPTY CWFL-2000BNPTY
    Voltage AC 1P 220-240V AC 1P 220-240V
    Frequency 50Hz 60Hz
    Current 3.4~20.3A 3.9~19.9A

    Max. power consumption

    3.61kW 3.84kW

    Heater power

    0.55kW+0.6kW
    Precision ±0.5℃
    Reducer Capillary
    Pump power 0.55kW 0.75kW
    Tank capacity 14L
    Inlet and outlet Rp1/2"+Rp1/2"

    Max. pump pressure

    4.4bar 5.3bar
    Rated flow 2L/min+>20L/min
    N.W. 69Kg
    G.W. 81Kg
    Dimension 70 X 47 X 89cm (L X W X H)
    Package dimension 73 X 57 X 105cm (LX W X H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    * Dual cooling circuit

    * Active cooling

    * Temperature stability: ±0.5°C

    * Temperature control range: 5°C ~35°C

    * Refrigerant: R-410A

    * User-friendly controller interface

    * Integrated alarm functions

    * Back mounted fill port and visual water level

    * Optimized for high performance at low temperatures

    * Ready for immediate use

    Optional Items

                  

     Heater

     

                   

    Filter

     

                  

     US standard plug / EN standard plug

     

    Product Details
    CWFL-2000 Laser Chiller Temperature Controller T-607
                                           

    Dual temperature control

     

    The intelligent control panel offers two independent temperature control systems. One is for controlling the temperature of the fiber laser and the other is for controlling the temperature of the optics.   

    CWFL-2000 Laser Chiller water inlet and outlet
                                           

    Dual water inlet and water outlet

     

    Water inlets and water outlets are made from stainless steel to prevent potential corrosion or water leakage.

    CWFL-2000 Laser Chiller Caster Wheels
                                           

    Caster wheels for easy mobility

     

    Four caster wheels offer easy mobility and unmatched flexibility. 

    Ventilation Distance

    Industrial Water Chiller Ventilation Distance

    Certificate
    TEYU Industrial Water Chiller Certificate
    Product Working Principle

    TEYU Laser Chiller CWFL-2000 Working Principle

    FAQ
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the water chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect