Reasons and solutions for poor refrigeration performance in industrial water chiller

Daily maintenance is quite necessary for the normal operation of the industrial refrigeration system. And poor refrigeration performance is the common problem for the industrial users. So what are the reasons and solutions for this kind of problem?

Teyu Industrial Water Chillers Annual Sales Volume

Industrial water chiller consists of condenser, compressor, evaporator, sheet metal, temperature controller, water tank and other components. It is widely used in plastic, electronics, chemistry, medicine, printing, food processing and many other industries that are closely related to our daily life. Daily maintenance is quite necessary for the normal operation of the industrial refrigeration system. And poor refrigeration performance is the common problem for the industrial users. So what are the reasons and solutions for this kind of problem?

Reason 1: Temperature controller of the industrial water cooler is faulty and unable to control temperature

Solution: Change for a new temperature controller.

Reason 2: The cooling capacity of the industrial refrigeration system is not big enough.

Solution: Change for a chiller model that has proper cooling capacity.

Reason 3: The compressor has a malfunction - not working/rotor being stuck/rotating speed slowing down)

Solution: Change for a new compressor or related parts.

Reason 4: The water temperature probe is faulty, not able to detect water temperature at real-time and the water temperature value is abnormal

Solution: Change for a new water temperature probe

Reason 5: If the poor performance occurs after the industrial water chiller is used for a certain period of time, that might be:

A.The heat exchanger is full of dirt

Solution: Clean the heat exchanger properly

B.The industrial water cooler leaks refrigerant

Solution: Find and weld the leakage point and refill with proper amount of refrigerant of the correct type

C.The operating environment of the industrial water cooler is too hot or too cold

Solution: Position the water chiller in a well-ventilated room where ambient temperature is below 40 degree C. 

Industrial Water Chiller CW-5200 for Cooling Small Laser Cutter

prev
How to drain down S&A Teyu small water chiller CW-5200?
Several tips on solving water blockage in laser water chiller
next

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
Contact us
email
Contact customer service
Contact us
email
cancel
Customer service
detect