loading
Language
Industrial Chiller CWFL-6000ENSW for 6kW Fiber Laser with Stable Performance
Industrial Chiller CWFL-6000ENSW for 6kW Fiber Laser with Stable Performance
Industrial Chiller CWFL-6000ENSW for 6kW Fiber Laser with Stable Performance
Industrial Chiller CWFL-6000ENSW for 6kW Fiber Laser with Stable Performance
Industrial Chiller CWFL-6000ENSW for 6kW Fiber Laser with Stable Performance
Industrial Chiller CWFL-6000ENSW for 6kW Fiber Laser with Stable Performance
Industrial Chiller CWFL-6000ENSW for 6kW Fiber Laser with Stable Performance
Industrial Chiller CWFL-6000ENSW for 6kW Fiber Laser with Stable Performance

Industrial Chiller CWFL-6000ENSW for 6kW Fiber Laser with Stable Performance

TEYU CWFL-6000ENSW water-cooled chiller is specifically engineered for 6000W fiber laser systems, where heat load and continuous operation demands are high. It delivers precise and stable temperature control to efficiently dissipate heat from the laser source and key optical components, helping maintain cutting quality, beam stability, and reliable performance while reducing the risk of downtime.

With dual-circuit cooling and an industrial-grade design, the CWFL-6000ENSW ensures balanced temperature management under heavy workloads. It supports environmentally compliant refrigerants and provides a dependable cooling solution that improves processing consistency and supports long-term, stable operation.

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    water-cooled Chiller CWFL-6000ENSWTY

    Ideal for Cooling 2kW Fiber Laser Machine

    CE-cetified chiller

    Model: CWFL-6000ENSWTY

    Refrigerant: R-410A/R-32

    Machine Size: 104 × 71 × 124 cm (L × W × H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    water cooled chiller for 6000w fiber laser systems
    water cooled chiller for 6000w fiber laser systems
    water cooled chiller for 6000w fiber laser systems
    Industrial Chiller CWFL-6000ENSW for 6kW Fiber Laser with Stable Performance 7

    Environmentally friendly refrigerant

    未标题-6 (2)

    Small size with large cooling capacity

    Industrial Chiller CWFL-6000ENSW for 6kW Fiber Laser with Stable Performance 9

    Low noise level, stable working performance

    1 (8)

    Satisfy the operating requirements of enclosed environment

    Product Parameters

    Model

    CWFL-6000ENSWTY

    Voltage

    AC 1P 220~240V

    Frequency

    50Hz

    Current

    2.3~16.2A

    Max. power consumption

    7.2kW

    Heater power

    1kW+1.8kW

    Precision

    ±1℃

    Refrigerant

    R-410A/R-32

    Reducer

    Capillary

    Pump power

    1.1kW

    Tank capacity

    70L

    Inlet and outlet

    Rp1/2"+Rp 1"*2

    Max. pump pressure

    6.15 bar

    Rated flow

    1.5L/min + >50L/min

    N.W.

    147kg

    Dimension

    104 × 71 × 124 cm (L × W × H)

    G.W.

    175kg

    Package dimension 112 × 82 × 150 cm (L × W × H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    More details

    Dual temperature control


    The intelligent control panel offers two independent temperature control systems. One is for controlling the temperature of the fiber laser and the other is for controlling the temperature of the optics.

    Dual temperature control T-801F

    Dual water inlet and water outlet


    Water inlets and water outlets are made from stainless steel to prevent potential corrosion or water leakage.

    Dual water inlet and water outlet

    Caster wheels for easy mobility


    Four caster wheels offer easy mobility and unmatched flexibility.

    Caster wheels for easy mobility

    Certificate

    Industrial Chiller Certificate

    Chiller Working Principle

    Industrial Chiller Working Principle

    Chiller Ventilation Distance

    Industrial Chiller Ventilation Distance

    FAQ

    1
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    2
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    3
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    4
    What is the ideal room temperature for the water chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    5
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

    We're here for you when you need us. 

    Please complete the form to contact us, and we'll be happy to help you. 

    Related Products
    no data
    Home     |    Products     |    SGS & UL Chiller     |    Cooling Solution    |    Company     |    Resource     |    Sustainability
    Copyright © 2026 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect