Reliable Water Cooled Chiller for 2000W Fiber Laser to Ensure Stable Operation
Reliable Water Cooled Chiller for 2000W Fiber Laser to Ensure Stable Operation

Reliable Water Cooled Chiller for 2000W Fiber Laser to Ensure Stable Operation

For 2000W fiber laser systems, stable cooling is essential to maintain cutting accuracy, output consistency, and continuous operation. TEYU CWFL-2000ANSW water-cooled chiller is specifically designed for this power range, delivering precise temperature control of ±0.5°C to effectively remove heat from both the laser source and optics. This helps prevent common issues such as power fluctuation, thermal drift, and unexpected downtime in industrial production.

Equipped with dual-circuit cooling and using refrigerants like R-410A or R-32 (with R-32 meeting GWP ≤750 requirements in Europe and the US), TEYU CWFL-2000ANSW supports both performance and environmental compliance. For global users, this means a reliable, energy-efficient cooling solution that ensures stable laser operation while aligning with increasingly strict sustainability standards.

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    water-cooled Chiller CWFL-2000ANSWTY

    Ideal for Cooling 2kW Fiber Laser Machine

    CE-cetified chiller

    Model: CWFL-2000ANSWTY

    Refrigerant: R-410A/R-32

    Machine Size: 70 X 47 X 89cm (L X W X H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    water cooled chiller for 2000w fiber laser
    water cooled chiller for 2000w fiber laser
    water cooled chiller for 2000w fiber laser
    Reliable Water Cooled Chiller for 2000W Fiber Laser to Ensure Stable Operation 7

    Environmentally friendly refrigerant

    未标题-6 (2)

    Small size with large cooling capacity

    Reliable Water Cooled Chiller for 2000W Fiber Laser to Ensure Stable Operation 9

    Low noise level, stable working performance

    1 (8)

    Satisfy the operating requirements of enclosed environment

    Product Parameters

    Model

    CWFL-2000ANSWTY

    Voltage

    AC 1P 220~240V

    Frequency

    50Hz

    Current

    3.1~11.8A

    Max. power consumption

    2.41kW

    Heater power

    0.55kW

    Precision

    ±0.5℃

    Refrigerant

    R-410A/R-32

    Reducer

    Capillary

    Pump power

    0.37kW

    Tank capacity

    14L

    Inlet and outlet

    Rp1/2"*2+Rp1"

    Max. pump pressure

    3.6 bar

    Rated flow

    1.5L/min + >20L/min

    N.W.

    62kg

    Dimension

    70 × 48 × 81 cm (L × W × H)

    G.W.

    73kg

    Package dimension 73 × 57 × 105 cm (L × W × H)
     

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    More details

    Dual temperature control


    Our in-house designers and engineers have produced countless great designs for customers from different industries.

    温控器T-801F

    Dual water inlet and water outlet


    Water inlets and water outlets are made from stainless steel to prevent potential corrosion or water leakage.

    出入水口

    Caster wheels for easy mobility


    Four caster wheels offer easy mobility and unmatched flexibility.

    脚轮

    Certificate

    11 (2)

    Chiller Working Principle

    CWFL-6000ENSW-1

    Chiller Ventilation Distance

    放置图

    FAQ

    1
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    2
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    3
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    4
    What is the ideal room temperature for the water chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    5
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

    We're here for you when you need us. 

    Please complete the form to contact us, and we'll be happy to help you. 

    Related Products
    no data
    Home     |    Products     |    SGS & UL Chiller     |    Cooling Solution    |    Company     |    Resource     |    Sustainability
    Copyright © 2026 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect