loading
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling
Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling

Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling

Comparing with traditional air cooled chiller, industrial water cooled chiller doesn't need a fan to cool the condenser, reducing noise and the heat emission to the operating space, which is more green energy-saving. CW-6200ANSW industrial chiller uses external circulating water working with the internal system for efficient refrigeration, smaller size with large cooling capacity with precise PID temperature control of ±0.5°C and less space occupation. It can satisfy the cooling applications like medical instruments and semiconductor laser processing machines that are operating in enclosed environment such as dust-free workshop, laboratory, etc. 

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    Water Cooled Chiller CW-6200ANSW Quiet Operation ±0.5°C Precision Cooling

    Model: CW-6200ANSW

    Machine Size: 67X47X80cm (L X W X H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    Model CW-6200ANSW
    Voltage AC 1P 220-240V
    Frequency 50Hz
    Current 2.5~19.9A

    Max. power consumption

    3.52kW


    Compressor power

    1.75kW
    2.38HP



    Nominal cooling capacity

    22519Btu/h
    6.6kW
    5674Kcal/h
    Refrigerant R-410A
    Precision ±0.5℃
    Reducer Capillary
    Pump power 0.37kW
    Tank capacity 22L
    Inlet and outlet Rp1/2"+ Rp 1/2"
    Max. pump pressure 3.6bar
    Max. pump flow 75L/min
    N.W. 67Kg
    G.W. 79Kg
    Dimension 67X47X80cm (L X W X H)
    Package dimension 73X57X105cm (L X W X H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    * Cooling capacity: 6600W                            

    * Active cooling                                      

    * Control accuracy: ±0.5°C

    * Temperature control range: 5°C ~35°C

    * Small size with large cooling capacity                      

    *Stable working performance with low noise level and long lifespan                           

    * High efficiency with low maintenance          

    * No heat interference to the operating room

    Optional Items

                  

     Heater

     

                   

    Filter

     

                  

     US standard plug / EN standard plug

     

    Product Details
    Water Cooled Chiller CW-6200ANSW Digital temperature controller
                                           

    Digital temperature controller

     

    The digital temperature controller offers high precision temperature control of ±0.5°C.

    Water Cooled Chiller CW-6200ANSW Dual water inlet and water outlet
                                           

    Dual water inlet and water outlet

     

    Water inlets and water outlets are made from stainless steel to prevent potential corrosion or water leakage. 

    Water Chiller CW-6200ANSW with Modbus RS485 communication
                                           

    Modbus RS485 communication port integrated in the electrical connecting box

     

    The RS485 communication port integrated in the electrical connecting box enables communication with the equipment to be cooled.

    Certificate
    Water Chiller CW-6200ANSW Certificate
    Product Working Principle

    Water Chiller CW-6200ANSW Product Working Principle

    FAQ
    Is S&A Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect